posted on 2024-10-30, 07:32authored byMilana Guteša Božo, Agustin Valera-Medina
<p>Data to determine the best cycle configuration in a humidified ammonia/hydrogen gas turbine have been generated to address the inefficiencies of the use of ammonia-blends in power generation. The data contains results of chemical kinetics through a Chemical Reaction Network assessed under high pressure, high temperature conditions using a 70-30 ammonia-hydrogen (vol%) humidified blend. Several efficiencies (mechanical, combustion, turbine expansion, cooling, steam injection, etc.) are also determined, analyzed with variations of 5%, and compared, providing guidance for improvement of these units. <br></p><p>Research results based upon these data are published at https://doi.org/10.3390/en13215749</p><p><br></p>
Funding
Storage of ammonia for energy (SAFE), AGT pilot (2020-01-06 - 2025-05-02); Valera Medina, Agustin. Funder: Engineering and Physical Sciences Research Council