These files for the data collected upon the investigation of the use of polycrystalline diamond within single material micro-hotplate structures. The data is organised by device number and characterisation technique, with the spreadsheet entitled "Samples" detailing the design and testing parameters of each device.
Data include: - SEM micrographs of the devices. - Raman spectrometer and monochromator spectra obtained upon biasing.
- IV traces obtained upon biasing.
- Micrographs obtained upon biasing.
- Raman spectra investigating device degredation.
- Oscilloscope traces obtained during thermalisation tests.
Research results based upon these data are published at https://doi.org/10.1002/smll.202303976
Funding
Making a miniature sun (2021-01-01 - 2023-12-31); Williams, Oliver. Funder: Engineering and Physical Sciences Research Council