Direct-write projection lithography of quantum dot micropillar single photon sources: data

Download (1.69 MB)

The data are part of a series of experiments that charactrise the properties of semiconductor devices known as micropillars. The Q-factors measured are a figure of merit for the quality of the sidewall roughness of the etched structures (Fig.2). Further to that the properties of semiconductor nanostructures enclosed within the micropillars are neasured, using the second order correlation of the photons emitted along with the non-classical interference observed between subsequent photons produced by the quantum dot micropillar devices (Fig.3), reflecting the quality of the photons produced.

The file is structured as follows each sheet corresponds to a part of each figure found within the manuscript with title "Direct-write projection lithography of quantum dot micropillar single
photon sources", e.g. Fig.2(a), the detailed description may be found below.

Sheet Fig.2(a): in column A the wavelength and in B the counts for the mesured data, in D the wavelength and E the corresponding values for the fitted data.

Sheet Fig.2(b): in column A the wavelength and in B the normalised reflectivity for the mesured data, in E the wavelength and F the corresponding values for the fitted data.

Sheet Fig.2(c): in column A the diameter of the micropillars measured, in B the measured Q-factor for each micropillar and in C the corresponding error for the measured Q, in E the diameter and F the corresponding values for the fit to the model used.

Sheet Fig.2(d): in column A the diameter of the micropillars measured, in B the measured Q-factor for each micropillar and in C the corresponding error for the measured Q, in E the diameter and F the corresponding values for the fit to the model used.

Sheet Fig.2(d): in column A the diameter of the micropillars measured, in B the measured Q-factor for each micropillar and in C the corresponding error for the measured Q, in F the diameter and G the corresponding values for the fit to the model used.

Sheet Fig.3(a) The square root of power applied in column A and the measured count-rate in column B.

Sheet Fig.3(b) In column A the time difference between the coincidences and in B the normalised g2.

Sheet Fig.3(d) In column A the time difference between the excitation pulse and the fluorescence bin Counts in B. In column D the wavelength and in Column E the counts measured for the CW resonant scattering and cross-polarised detection for the doublet under investigation, for the plotted inset figure.

Sheet Fig.3(e) In column A the time difference between the coincidencesand in B the normalised g2 for orthogonally polarised arms of the HOM setup.

Sheet Fig.3(f) In column A the time difference between the coincidences and in B the normalised g2 for co-polarised arms of the HOM setup.

Research results based upon these data are published at http://doi.org/10.1063/5.0155968


Funding

EPSRC Centre for Doctoral Training in Compound Semiconductor Manufacturing

Engineering and Physical Sciences Research Council

Find out more...

Manufacturing scalable semiconductor quantum light sources

Engineering and Physical Sciences Research Council

Find out more...

EPSRC Hub in Quantum Computing and Simulation (2019-12-01 - 2025-05-31); Bennett, Anthony. Funder: Engineering and Physical Sciences Research Council

History

Specialist software required to view data files

Excel

Usage metrics

    School of Engineering

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC